DuPont™ Tyvek® HomeWrap®

Sturdy Housewrap Engineered for Energy Efficiency

DuPont™ Tyvek® HomeWrap®

Sturdy Housewrap Engineered for Energy Efficiency

<br><b>DuPont™ Tyvek® HomeWrap®</b> is the original house wrap, leveraging advanced material science to keep air and water out while allowing water vapor to escape. This contributes to enhanced building durability by protecting homes from damaging wind and rain that can penetrate exterior cladding. <br><br> <b>Tyvek® HomeWrap®</b> is uniquely engineered by spinning extremely fine high-density polyethylene (HDPE) fibers that are fused together to form a strong, uniform web. This robust structure creates millions of tiny pores that resist bulk water and air penetration while allowing moisture vapor to pass through. <br><br> Additionally, <b>Tyvek® HomeWrap®</b> can reduce home energy bills by controlling air flow and water intrusion, thereby improving insulation performance and HVAC efficiency. It is designed to keep homes cool in the summer, warm in the winter, and dry all year round.
 
 
 

Resources

 
 
 
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Unit Width Length
Roll 3 ft. 100 ft.
Roll 3 ft. 165 ft.
Roll 5 ft. 200 ft.
Roll 9 ft. 100 ft.
Roll 9 ft. 150 ft.
Roll 10 ft. 100 ft.
Roll 10 ft. 150 ft.
 
 
 

Testing

<b>Tyvek® HomeWrap™</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:

TEST METHOD TEST TITLE PROPERTY RESULTS
AIR
ASTM E1677 Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls Air Penetration Resistance Type 1
cfm/ft2 @ 1.57 psf
ASTM E2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Air Penetration Resistance < .004 cfm/ft2
@ 1.57 psf
TAPPI T460 Air resistance of paper (Gurley method) Air Penetration Resistance 1200 sec/100cc
FIRE
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics Class A Index Flame Spread = 15
Smoke Developed = 15
STRENGTH
ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting Breaking Strength 30/30
lbs/in
ASTM D1117 Standard Guide for Evaluating Nonwoven Fabrics Tear Resistance 8/6 lbs
TAPPI T-410 Grammage of Paper and Paperboard (Weight per Unit Area) Basis Weight 1.8 oz/yd2
WATER
AATCC 127 Test Method for Water Resistance: Hydrostatic Pressure Water Penetration Resistance 250 cm
ASTM E2273 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies Drainage Efficiency ICC-ES AC 24 Section 6.11 ICC-ES AC 235 Section 4.5 >90%
Pass
Pass
ASTM E2556 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment Vapor Permeability (Type II Compliant) Pass
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission Method A 400 g/m2-24 hrs
56 perms
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission Method B 370 g/m2-24 hrs
54 perms
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 