Features & Benefits
Specifications
Unit | Width | Length |
---|---|---|
Roll | 5 ft. | 200 ft. |
Roll | 10 ft. | 125 ft. |
<b>Tyvek® CommercialWrap®</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:
TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
---|---|---|---|
AIR | |||
ASTM E1677 | Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls | Air Penetration Resistance | Type 1 cfm/ft2 @ 1.57 psf |
ASTM E2178 | Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials | Air Penetration Resistance | .001 cfm/ft2 @ 1.57 psf |
ASTM E2357 | Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies | Air Penetration Resistance | <0.01 cfm/ft2 @ 1.57 psf |
ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | Wall Assembly Air Penetration Resistance | <0.01 cfm/ft2 @ 1.57 psf |
TAPPI T460 | Air resistance of paper (Gurley method) | Air Penetration Resistance | >1500 sec/100cc |
FIRE | |||
NFPA 285 | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components | Flame Propagation/Multiple Assemblies | Pass |
ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Surface Burning Characteristics Class A Index | Flame Spread = 15 Smoke Developed = 25 |
ASTM E1354 | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter | Peak Heat Release Total Heat Release Effective Heat of Combustion | <150 kW/m2 <20 MJ/m2 <18 MJ/kg |
STRENGTH | |||
ASTM D882 | Standard Test Method for Tensile Properties of Thin Plastic Sheeting | Breaking Strength | 38/35 lbs/in |
ASTM D1117 | Standard Guide for Evaluating Nonwoven Fabrics | Tear Resistance | 12/10 lbs |
TAPPI T-410 | Grammage of Paper and Paperboard (Weight per Unit Area) | Basis Weight | 130 (2.7) gms/m2 (oz/yd2) |
WATER | |||
AATCC 127 | Test Method for Water Resistance: Hydrostatic Pressure | Water Penetration Resistance | 280 cm |
ASTM E2273 | Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies | Drainage Efficiency ICC-ES AC 24 Section 6.11 ICC-ES AC 235 Section 4.5 | >90% Pass Pass |
ASTM E2556 | Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment | Vapor Permeability (Type II Compliant) | Pass |
ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | Wall Assembly Water Penetration Resistance | No leakage Tested to 15 psf |
ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Water Vapor Transmission Method A | 163 g/m2-24 hrs 23 perms |
ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Water Vapor Transmission Method B | 200 g/m2-24 hrs 28 perms |