DuPont™ Tyvek® CommercialWrap®

High Performance Water-Resistive and Air Barrier (WRB) and Engineered to Stand Up to the Commercial Job Site

DuPont™ Tyvek® CommercialWrap®

High Performance Water-Resistive and Air Barrier (WRB) and Engineered to Stand Up to the Commercial Job Site

<br>Engineered to provide excellent performance as an air and water barrier, <b>DuPont™ Tyvek® CommercialWrap®</b> delivers the added strength and durability needed in commercial construction. It provides an ideal balance of air and moisture management resulting in more durable and energy efficient structures. <br><br> <b>Tyvek® CommercialWrap®</b> is made from 100% flash spunbonded high density polyethylene fibers which have been fused together by heat and pressure, without binders or fillers, into a tough durable sheet structure. Additives have been incorporated into the polyethylene to provide ultraviolet light resistance.
 
 
 

Resources

 
 
 
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Unit Width Length
Roll 5 ft. 200 ft.
Roll 10 ft. 125 ft.
 
 
 

Testing

<b>Tyvek® CommercialWrap®</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:

TEST METHOD TEST TITLE PROPERTY RESULTS
AIR
ASTM E1677 Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls Air Penetration Resistance Type 1
cfm/ft2 @ 1.57 psf
ASTM E2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Air Penetration Resistance .001 cfm/ft2
@ 1.57 psf
ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies Air Penetration Resistance <0.01 cfm/ft2
@ 1.57 psf
ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen Wall Assembly Air Penetration Resistance <0.01 cfm/ft2
@ 1.57 psf
TAPPI T460 Air resistance of paper (Gurley method) Air Penetration Resistance >1500 sec/100cc
FIRE
NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components Flame Propagation/Multiple Assemblies Pass
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics Class A Index Flame Spread = 15
Smoke Developed = 25
ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter Peak Heat Release Total Heat Release Effective Heat of Combustion <150 kW/m2
<20 MJ/m2
<18 MJ/kg
STRENGTH
ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting Breaking Strength 38/35
lbs/in
ASTM D1117 Standard Guide for Evaluating Nonwoven Fabrics Tear Resistance 12/10 lbs
TAPPI T-410 Grammage of Paper and Paperboard (Weight per Unit Area) Basis Weight 130 (2.7) gms/m2
(oz/yd2)
WATER
AATCC 127 Test Method for Water Resistance: Hydrostatic Pressure Water Penetration Resistance 280 cm
ASTM E2273 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies Drainage Efficiency ICC-ES AC 24 Section 6.11 ICC-ES AC 235 Section 4.5 >90%
Pass
Pass
ASTM E2556 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment Vapor Permeability (Type II Compliant) Pass
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Wall Assembly Water Penetration Resistance No leakage
Tested to 15 psf
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission Method A 163 g/m2-24 hrs
23 perms
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission Method B 200 g/m2-24 hrs
28 perms
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 