<br><b>DuPont™ Thermax™ XARMOR™ (ci) Exterior Polyisocyanurate Insulation</b> is the toughest insulation for the patented Thermax™ Wall System. Designed for continuous insulation, <b>Thermax™ XARMOR™ (ci)’s</b> glass-fiber-reinforced polyisocyanurate foam core is homogenous – featuring finer cell size and better cell orientation, reducing voids and knit lines – resulting in one of the highest R-values available for immediate insulation and weather protection on the job site, as well as long-term thermal performance. <br><br> <b>Thermax™ XARMOR™ (ci) Insulation</b> is also the only Thermax™ Insulation with a dark exterior facer optimized to go behind rain screen exteriors. Its integral, durable thermoset-coated aluminum facer provides a drainage plane, water-resistive barrier and exterior sheathing; eliminating the need for a membrane, building wrap or exterior gypsum. Boasting a strong 4.0 mil embossed, acrylic-coated exterior foil facer, <b>Thermax™ XARMOR™ (ci) Insulation</b> provides builders with more durability for long-term performance. <br><br> With its low perm rating and high insulating value, <b>Thermax™ XARMOR™ (ci) Insulation</b> can help reduce the potential for condensation within the wall assembly. Thermax™ is also manufactured using a distinct free-rise technology using a unique fiberglass core for better product consistency, durability and fire performance than generic polyisocyanurate insulations.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Thickness Width Length R-Value Edge Treatment
1.0 in. 4 ft. 8 ft. 6.9 Square Edge
1.55 in. 4 ft. 8 ft. 10.2 Square Edge, Shiplap
2.0 in. 4 ft. 8 ft. 13.0 Square Edge, Shiplap
2.5 in. 4 ft. 8 ft. 16.0 Shiplap
3.0 in. 4 ft. 8 ft. 19.0 Shiplap

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.

 
 
 

Testing

<b>Thermax™ XARMOR™ (ci) Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
UL 723 Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics1 Flame Spread ≤ 25
Smoke Developed ≤ 450
Core and Finished Product
NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components Fire Progagation - Exterior2 Pass
NFPA 286 Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth Fire Progagation - Interior Pass
THERMAL
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance 1 inch @ 75°F mean temp 6.9 ft2
•h•°F/Btu, R-value, min.
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Dimensional Stability 0.2% linear (length & width)
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength 25 psi
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 75 psi
ASTM D1623 Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics Tensile Strength 500 psf, min.
AIR
ASTM E2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Rate of Leakage <0.001 L/s*m2, max
ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies Air Leakage No Leakage
ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen Rate of Leakage <0.02 L/s*m2, max
WATER
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance. 0.01 perm
ASTM C209 Standard Test Methods for Cellulosic Fiber Insulating Board Water Absorption 0.1% volume
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Water Penetration Pass

1Calculated flammability values for this or any other material are not intended to represent hazards that may be present under actual fire conditions.

2See Jensen Hughes engineering judgement

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 