DuPont™ Thermax™ White Finish NH Insulation

Non-Halogenated (NH), Embossed White Acrylic Coated, Glass-Fiber Reinforced Polyiso Foam Insulation

thermax-white-finish-product-logo-image1.jpg
thermax-white-finish-product-logo-image2.jpg
thermax-white-finish-product-logo-image3.jpg
thermax-white-finish-product-logo-image4.jpg

DuPont™ Thermax™ White Finish NH Insulation

Non-Halogenated (NH), Embossed White Acrylic Coated, Glass-Fiber Reinforced Polyiso Foam Insulation

<br><b>DuPont™ Thermax™ White Finish NH Polyisocyanurate Insulation</b> is designed for use as both an insulation and interior finish system. It is suitable for interior masonry or concrete walls, as well as walls and ceilings in metal, wood post frame, and concrete or masonry buildings, adhering to building code requirements. <br><br> <b>Thermax™ White Finish NH Insulation</b> features a glass-fiber-reinforced polyisocyanurate foam core, with one side faced with 1.25 mil embossed white acrylic-coated aluminum and the other with 0.9 mil smooth aluminum. The white embossed surface is aesthetically pleasing and easy to clean, capable of withstanding pressure washing up to 1,000 psi. It also meets USDA requirements for incidental food contact when used on surfaces like floors, walls, and ceilings. <br><br> Thermax™ Brand Insulations are manufactured using an exclusive free-rise process, resulting in a closed-cell foam with enhanced fire performance. This foam core, combined with durable facers, provides high R-value, excellent dimensional stability, and moisture resistance. When paired with the appropriate joint closure system, <b>Thermax™ White Finish NH Insulation's</b> low perm rating effectively prevents moisture condensation within and behind the insulation.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 
 
 
 

Testing

<b>Thermax™ White Finish NH Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics1 Flame Spread ≤ 25
Smoke Developed ≤ 450
Core and Finished Product
UL 1715 Standard for Safety Fire Test of Interior Finish Material Fire Progagation - Interior Pass
NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components Fire Progagation - Exterior2 Pass
NFPA 286 Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth Fire Progagation - Interior Pass
NFPA 268 Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source Ignitabiilty - Exterior Pass
THERMAL
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance 1 inch @ 75°F mean temp3 6.6 ft2
•h•°F/Btu, R-value, min.
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Dimensional Stability 0.2% linear (length & width)
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength4 20 psi
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 50 psi
ASTM D1623 Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics Tensile Strength 500 psf, min.
AIR
ASTM E2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Leakage rates less than 0.0001 L/s/m2
at a test pressure of 75 Pa.
Pass
ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies Air Leakage No Leakage
WATER
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance. 0.01 perm
ASTM C209 Standard Test Methods for Cellulosic Fiber Insulating Board Water Absorption 0.1% volume, max.
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Water Penetration Pass

1Calculated flammability values for this or any other material are not intended to represent hazards that may be present under actual fire conditions.

2See Jensen Hughes engineering judgement

3R-value of 1.0-inch of foam measured @ 75°F mean temperature, determined in accordance with ASTM C518 after aging for 90 days @ 140°F.

4Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 