<br><b>DuPont™ Styrofoam™ Brand Panel Core 30 Extruded Polystyrene (XPS) Insulation</b> is a closed-cell, high performance core material featuring a proprietary extrusion process facilitating precise control of parameters like density, cell size and cell orientation. This process yields foam boards that can stand up to the most demanding and extensive array of composite panel applications. <p> <b>Styrofoam™ Brand Panel Core 30 XPS Insulation</b> is supplied in sheets that have been carefully engineered and planed to precise tolerances for an exceptional bonding surface. Its closed-cell structure resists absorption of water, which helps maintain panel integrity and insulating properties in low temperature applications and other environments with high humidity and moisture conditions. The foam also resists absorption of adhesives, so less glue is required for effective, long-lasting adhesion of facer materials.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 
 
 
 

Testing

<b>Styrofoam™ Brand Panel Core 30 XPS Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
UL 723 Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics Flame Spread ≤ 25
Smoke Developed ≤ 450
THERMAL
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance per inch: fresh @ 55 °F (13° C) min. fresh @ 20 °F (-7 °C) min.1 5.0 ft2•h•°F/Btu, R-value, min.
8.0 ft2•h•°F/Btu, R-value, min.
ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer Coefficient of Linear Thermal Expansion 3.5 x 10-5
in/in•°F
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Change in Dimensions 2.0% change, max.
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength2 30 psi, min.
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 55 psi, min., extruded
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Modulus 1,600 psi, min., extruded
ASTM D1623 Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics Tensile Strength 65 psi, min., vertical
ASTM C273 Standard Test Method for Shear Properties of Sandwich Core Materials Shear Strength 35 psi, min.
ASTM C273 Standard Test Method for Shear Properties of Sandwich Core Materials Shear Modulus 400 psi, min.
WATER
ASTM C272 Standard Test Method for Water Absorption of Core Materials for Sandwich Construction Water Absorption 0.1% by volume, max.
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance3 1.5 perm, max.

1R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam™ Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 