DuPont™ Styrofoam™ Brand Freezermate™ XPS Insulation

Subfloor Thermal Insulation for Low-Temperature Applications U.S. HFC Compliant Formulation

styrofoam-brand-freezermate-product-logo-image1.jpg
styrofoam-brand-freezermate-product-logo-image2.jpg
styrofoam-brand-freezermate-product-logo-image3.jpg

DuPont™ Styrofoam™ Brand Freezermate™ XPS Insulation

Subfloor Thermal Insulation for Low-Temperature Applications U.S. HFC Compliant Formulation

<br><b>DuPont™ Styrofoam™ Brand Freezermate™ XPS Extruded Polystyrene (XPS) Insulation</b> is a closed-cell, extruded polystyrene foam insulation with smooth, high density skins. <p> Available in a compressive strength of 30 psi, <b>Styrofoam™ Brand Freezermate™ 30 XPS Insulation</b> features exceptional moisture resistance and R-value retention. All Styrofoam™ Brand Freezermate™ products have excellent insulating characteristics, high resistance to water and water vapor, excellent freeze-thaw resistance, superior compressive strength and long-term durability. <p> <b>Styrofoam™ Brand Freezermate™ 30 XPS Insulation</b> can also be used in most static and dynamic loading situations for flooring applications. Because the rigid foam insulation boards resist even severe forms of moisture penetration in freezer and cooler construction, they offer long-term R-values superior to other types of thermal insulation.
 
 
 

Resources

 
 
 
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Thickness Width Length R-Value Edge Treatment
3 in. 4 ft. 8 ft. 15 Square Edge
 
 
 

Testing

<b>Styrofoam™ Brand Freezermate™ XPS Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
UL 723 Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics Flame Spread ≤ 25
Smoke Developed ≤ 450
THERMAL
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance per inch @ 75°F mean temp1 5.0 ft2
•h•°F/Btu, R-value, min.
ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer Coefficient of Linear Thermal Expansion 3.5 x 10-5
in/in•°F
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Change in Dimensions 2.0% change, max.
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength2 30 psi, min.
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 50 psi, min.
WATER
ASTM C272 Standard Test Method for Water Absorption of Core Materials for Sandwich Construction Water Absorption 0.3% by volume, max.
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance3 1.5 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam™ Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 