Features & Benefits
Specifications
Unit | Unit Size | Units per Case | Cases per Pallet | Units per Pallet |
---|---|---|---|---|
Can | 24oz can | 12 | 64 | 768 |
Can | 30oz can | 12 | 64 | 768 |
<b>DuPont™ Enerfoam™ Professional Foam Sealant </b> exhibits physical properties as indicated inin the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-866-583-2583 when additional guidance is required for writing specifications that include this product.
TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
---|---|---|---|
THERMAL | |||
ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | Thermal Resistance | 0.26 per inch @ 75°F mean temp., Btu•in/ft2•hr•°F, min |
ASTM D2126 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging | Dimensional Stability | 14.31% (100°F/100%RH@2wks) 0.41% (-40°F/ambRH@2wks) |
STRENGTH | |||
ASTM C203 | Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation | Flexural Strength | 8.8 psi min. (parallel to rise) |
ASTM D1621 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics | Compressive Strength | 9.3 psi (parallel to rise) |
ASTM D1623 | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics | Tensile Strength | 14.4 psi (parallel to rise) |
ASTM D1622 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics | Core Density | 1.01 pcf |
WATER | |||
ASTM D2842 | Test Method for Water Absorption of Rigid Cellular Plastics | Water Absorption | 6.4 % per volume |
GENERAL | |||
ASTM D2856 | Standard Test Method for Open-Cell Content of Rigid Cellular Plastics by the Air Pycnometer | Closed Cell Content | 0.8 |