<br><b>DuPont™ StraightFlash™</b> is an innovative, single-sided, self-adhered flashing solution that bridges the gap between the rough opening and building envelope to protect against water intrusion around heads and jambs of rectangular doors, windows and other gaps. By sealing vulnerable areas around openings, <b>DuPont™ StraightFlash™</b> can help improve the durability and energy efficiency of both homes and commercial structures. <br><br> <b>DuPont™ StraightFlash™ flashing</b> combines a DuPont™ Tyvek® topsheet with a 100% butyl-based adhesive layer, merging the strength, durability and water resistance of Tyvek® material with the convenience and flexibility of a self-adhered flashing. The result: premium door and window flashing protection that helps keeps rain out and integrates seamlessly with other DuPont™ air and water barriers in a complete building envelope system.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Unit Width Length Units per Case Cases per Pallet Units per Pallet
Roll 4 in. 150 ft. 4 24 96
Roll 9 in. 125 ft. 4 8 32
 
 
 

Testing

<b>DuPont™ StraightFlash™</b> exhibits physical properties as indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
AIR
ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies Assembly Air Leakage < 0.04 cfm/ft2
(0.2 L/s • m2)
WATER
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Installed System Water Intrusion Testing. NO leakage at 718 Pa (15 psf)
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Installed System Water Intrusion Testing (after thermal aging (0-120°F) NO leakage at 718 Pa (15 psf)
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeability < 1 perm
(< 60 ng/Pa.sec.m2)
GENERAL
AAMA 711 Specification for Self-Adhering Flashing Used for Installation of Exterior Wall Fenestration Products Dupont Flashing Systems Products Meet the AAMA 711 Material Standard at the Highest Classification Levels Class A (no primer)
Level 3 Thermal Exposure
(80°C/176°F for 7 days)

Note:- *Tested in a wall assembly containing a window. Consult DuPont for primer recommendations

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 