Physical Properties

  Method Unit Value
Air Leakage Resistance<sup></sup> ASTM E2357 - Pass
Air Infiltration at 75 Pa<sup></sup> ASTM E283 - 0.01 cfm/ft2 (0.1 L/s/m2)
Air Infiltration at 300 Pa<sup></sup> ASTM E283 - 0.04 cfm/ft2 (0.2L/s/m2)
Water Penetration at 6.27 psf (300 Pa)<sup>1</sup> ASTM 331 - Pass
Mold and Mildew<sup></sup> ASTM C1338 - Pass
Fastener Sealability<sup>2</sup> ASTM D1970 - Pass
Fire Resistance<sup>3</sup> NFPA 285 - Pass
Vapor Permeance (entire assembly)<sup></sup> ASTM E96, Procedure A - 0.5 Perms (grains/hr in Hg ft2)
Flame Spread/Smoke Developed Index (facer)<sup></sup> ASTM E84 - 0 / 0
Flame Spread/Smoke Developed Index (insulation)<sup></sup> ASTM E84 - 10 / 250
Thermal Resistance<sup></sup> ASTM C518 (ASTM-54) per inch 6.5
Foam Compression<sup></sup> ASTM D1621 (ASTM-65) psi 30
Fastener Withdrawal Capacity<sup>4</sup> ASTM D17614,5 - 284 lbs
Fastener Pull Through<sup>5</sup> ASTM D17614,5 - 505.2 lbs
Fastener Shear in Sheathing Only<sup></sup> ASTM D17614,5 - 519 lbs

1Total test duration two continuous hours.

2ArmorWall™ SP Plus FR SIS is self-sealing around cladding attachment fasteners

3ArmorWall™ SP Plus FR SIS passes NFPA 285 attached directly to the stud framing allowing most cladding installed to its exterior as inclusive to the NFPA 285 approved assembly.

4Average ultimate value after thermal cycling (10 cycles) provided

5Fastener data reflects attachment to the panel not attachment to structure.

 
 
 

Available Sizes

Thickness Width Length R-Value
3.75 48 96 R17
2.75 48 96 R11
4.25 48 96 R21
 
 
 

How can we help you?